A hybrid mobile lighting tower ready with a single-phase disel generator of 5 KVA / 7.5 KVA with Lithium Battery charging system to power the lights with automatic changeover.
Height of the Tower | 7 meter. | Type of Towers | Telescopic type, Flatbed trolley mounted. |
Material of Construction | M.S. Plates formed into square shaped tube. | Basic wind speed | 50 m/sec or 180 km/hr |
Height Variation factor | As per IS Code 875:1987 (Part 3). | Gust Factor | 1.15 |
Mean probable design life | 25 years. | No. of segments | Six |
Winch Mechanism | Manual / Motorised as required | Towing Type | Front fitting telescopic towing rod |
Number of Lights and Wattage | 6 nos of 200W LED flood light. | No of Cradle | One (having 2 levels) 6 nos lights (at least 4 lights can be fitted on one side of the cradle if required). |
Front wheel size and type | 2 nos of pneumatic (6×16 tyre size). | Rear wheel size and type | 2 nos of pneumatic (6×16 tyre size). |
Overall Weight | 1500 kg approx. | Dimension (L x W x H) | 5000 mm x 2000 mm x 3000 mm |
Hinging / Telescopic Arrangement | The system would have an arrangement for installing and maintaining lights at ground level. The tilting arrangement of the tower would be perfectly balanced and would not give any jerk or need a push / pull to activate the operation. | ||
Trolley Base | The trolley base would be fabricated from channel frame work. The base would be provided with suitable number of riggers of suitable extendable length to provide complete stability of towers when fully erected. The riggers after extension would be grounded with the help of screw jacks having suitable free base of steel. The trolley would be fitted with a tow-eye, tail light reflectors etc. | ||
Anti-rust treatment and Painting | The total tower structure shall be given anti rust treatment by painting after sand blasting. Before painting two coats of primer shall be applied. During final painting of complete tower structure standard safety color code shall be complied with so as to provide clear visibility to the operation of dumpers, dozers, tippers etc. for safety against collision/damage during night time. | ||
Mast Lighting Control panel (MLCP) | The MLCP shall be of outdoor type having IP 55 class of protection with incomer for power from mains / DG set. 30mA RCBO of adequate rating shall be provided as main incomer and MCBs shall protect the outgoing cables from short circuit. | ||
Luminaries | The long range, high intensity, energy saving LED flood light would be dust, moisture and vermin proof. The fitting would be complete with Die Cast Aluminum alloy Housing having high conductivity heat sinks, high performance PMMA lens, toughened front glass of 5 mm thickness, focusing arrangement. The fittings have type test Certificate including for photometry for all tests specified in type tests clause. The IP classification for the flood lights would be IP 66. |
Battery Voltage | 96 Volt DC | Battery Capacity | 100 Ah / 160 Ah |
Battery Chemistry | Lithium Ferro Phosphate | Battery Life Cycle | 2000 cycle |
Inverter Capacity | 8 KVA | Inverter Type | MPPT, Offgrid |
Output Voltage | 230 V AC (50 Hz) | Phase | Single |
Charging Time | 4 to 5 hrs. | Back-Up Time | 8 to 10 hrs. ( 6 lights of 200W LED) |
DG Set | 5 KVA / 7.5 KVA | Phase / Voltage | Single / 230 V AC |